Slide
Position Control
Products
ProMation Control
ProMation has developed several different control packages ranging from simple relays to sophisticated bus systems.
Duty Cycle and Products
ProMation offers a full range of duty cycles from continuous operation in the U Series to 30% duty cycle in the more simple on-off actuators.
System
On/Off/Jog
Duty Cycle
Modulating
Duty Cyle
Bus
Duty Cycle
Dual Acting Rotary (P1-P8)
AC 30% - DC 75%
75%
75% (P2+)
Dual Acting Rotary (P9-P13)
AC 30%
50%
50%
Spring Return
30%
30%
U-Series
100%
100%
100%
On—Off—Jog Control
System
Description
Products
PLCs (Programmable Logic Controllers):
Uses a relay to drive an actuator to its end of travel. Lack of signal drives in opposite direction
RO– Relay to Open—hot relay opens actuator
RC– Relay to Close—hot relay closes actuator
OPT-RO(PF)-(V)
OPT-RC(PF)-(V)
DCS (Distributed Control System)
Isolates a 3-30VDC incoming control signal to drive a P2 to P13 24, 120, or 230VAC actuator to its desired position
OPT-DSSRP213-(V)
SCADA (Supervisory Control
and Data Acquisition)
Sends the position of the actuator back to control. Can use common control analogue signals (4-20mA, 2-10VDC, 1-5VDC or the voltage signal from the position sensor (potentiometric).
Kit-OPT-420FB-(V)-(PF) Analogue
Kit-OPT-(PF)-(1, 5, 10)K Potentiometric
(1, 5, and 10 are the resistance of the pot)
*(PF)=Product Family
*(V)= Voltage, AC or DC
Modulating Control
System
Description
Product Family
Standard
1% Resolution, 4-20mA, 0-10, 2-10, 1-5VDC control signal and feedback
P1, P1.A , Spring Return
Advanced
0.5% Resolution, 4-20mA, 0-10, 2-10, 1-5VDC control signal and feedback, fault detection and indication, data logging, Modbus
P2-P13, AC Voltages
High Resolution
0.25% Resolution, 4-20mA, 0-10, 2-10, 1-5VDC control signal, direct and loop feedback, fault detection, Modbus
P2-P13, AC Voltages with -HR Option
P2-P8, DC Voltages
U-Series
0.5% Resolution, 4-20mA, 0-10, 2-10, 1-5VDC control signal and feedback, fault detection and indication, single wire control, Modbus
UM(B-D) All Voltages
UL(C-F) All Voltages
ULE-AVN7-EPBA
U Series, 100% duty cycle with On/Off/Jog, Modulating and Modbus control, Supercapacitor failsafe backup.
OPT-DSSRP213-120 (left)
Kit-OPT-420FB-120-P213 (right)
The dual relay and feedback modules allow low voltage DC SCADA systems to modulate 120VAC actuators without the need of a modulating controller in the actuator.
16138 Flight Path Drive Brooksville, Florida 34604 ⚫ P(352) 544-8436 F(352) 544-8439
www.promationei.com