P13 Quarter Turn Actuators
The P13 family of electric actuators are designed for load requirements of 40,000 inch pounds. The actuator comes standard with two auxiliary switches (form C), an internal low power heater, a NEMA 4X environmental rating, and in 120VAC, 230VAC 3 Phase, 380 VAC 3 Phase, and 480 VAC 3 phase supply voltages. The P13 family mechanical connections are ISO 5211 compliant. The P13 Series can be ordered as an on/off (two position) model that can be used in bump/jog applications as well. Models can also be ordered with an internal proportional control card that accepts a wide range of control signals and generates multiple feedback signals for field use.
REQUEST MORE INFO
- Description
- IOMs
- CAD & Dimensional Data
- Wiring Diagrams
- Product Nomenclature
- Product Family Matrix
- PROMATION BROCHURE
- CUT SHEETS
IOMs
IOM P13 120V ISO & IMP (TORQUE SWITCH)(IP68)(STAINLESS STEEL) WIRELESS
IOM P13 HV MODULATING NEMA 4/4X HIGH RESOLUTION ISO FEEDBACK (TORQUE SWITCH)
IOM P13 HV MODULATING NEMA 4/4X
IOM P13 ISO & IMP HV MODULATING NEMA 4/4X HIGH RESOLUTION (TORQUE SWITCH)(IP68)(STAINLESS STEEL)
IOM P13 ISO & IMP HV MODULATING NEMA 4/4X (TORQUE SWITCH)(IP68)(STAINLESS STEEL)
CAD & Dimensional Data
Wiring Diagrams
WD-850-00100 HV AC (TORQUE SWITCH) USE FOR P2-P13 HV N4/N7-TS
WD-850-00200 HV AC MODULATING USE FOR P2-P13 120/230PN4
WD-850-34501 120VAC NORMALLY CLOSED (RELAY TO OPEN) USE FOR P2-P13 120N4-RO
WD-850-34502 G120VAC NORMALLY OPEN (RELAY TO CLOSE) USE FOR P2-P13-120N4-RC
WD-850-P4S01F NON LINE VOLTAGE OPEN/CLOSE CONTROL 120/230VAC USE FOR DUAL RELAY P2-P13 DR SCADA
WD-858-09100 MOTOR CONTROL CENTER 480/3/60 (TORQUE SWITCH) USE FOR P2-P13 ALL/3/60 MCC-(TS)
WD-850-24161 120VAC W/ 4-20mA FEEDBACK USE FOR P2-13-120N4 W/4-20mA FB
WD-850-34502F 120VAC NORMALLY OPEN (RELAY TO CLOSE) USE FOR P2-P13-120N4-RC
WD-850-O4N00 120VAC WIRELESS OPEN CLOSE SWITCHING USE FOR P2-P13-120N4-WL
WD-850-O4601 120VAC PROFIBUS USE FOR P2-P13-120PFB-N4
WD-850-O42821 120 VAC PROPORTIONAL MODBUS CONTROL USE FOR P2-P13-120PN4-MODBUS
WD-850-OO101 B LV HV (+ACDC)(TORQUE SWITCH) USE FOR P2-P13-24/120/230N4/N7(+ACDC)-TS
WD-850-OO501 HV VAC OSCILLATING SINGLE WIRE ACTIVATION USE FOR P2-P13_WHI_HV OSCILLATION
WD-850-OO10101 NORMALLY CLOSED (RELAY TO OPEN) 120VAC/24VDC CONTROL USE FOR P2-P13-120N4-24VDC RO
WD-850-P4S01G NON-LINE VOLTAGE AND CONTROL FOR HV USE FOR DUAL RELAY P2-P13 DR SCADA
WD-850-P4161 120VAC W/ 4-20mA FEEDBACK USE FOR P2-P13-120N4 W/4-20mA FB
WD-850-P4222F 120VAC HIGH RESOLUTION PROPORTIONAL CONTROL USE FOR P2-P13-120PN4-HR
WD-850-P4522 HV VAC NORMALLY OPEN (RELAY CLOSE) LI TIMER USE FOR P2-P13-120/230N4-RC-LI
WD-858-09101 MOTOR CONTROL CENTER 480/3/60 (TORQUE SWITCH USE FOR P2-P13 ALL/3/60 MCC-(TS)
WD-850-54101 120VAC USE FOR P9-P13-120N4
WD-850-54201 120VAC MODULATING USE FOR P9-P13-120PN4
WD-850-94101 120VAC TORQUE SWITCH USE FOR P9-P13-120N4-TS
WD 840-04T03 A USE FOR P2-P13 WAIT TIMER CCW
Product Nomenclature
web product nomenclaturePROMATION BROCHURE
CUT SHEETS
Related products
Recent Posts
- Notes from a hotel room: the true cost of pneumatic actuation
- ProMation Engineering, Inc. offers a wide range of Explosion Proof Actuators
- Notes from a hotel room: The difference between electric and pneumatic valve actuators
- Spring Return Electric Actuators Meet Fire Standards for Tunnels
- New Sales Organization in Switzerland covering Europe, Middle East and Africa